Infrared Thermometer SAUTER JIT
Infrared thermometer for industry, environmental engineering and maintenance work
Choose your reference
- Temperature range
- -32 – 420 °C
- Resolution
- —
- Lead time
- Ships within 48 h
Optique 12:1
Measurement
- Reference
- JIT 100
- Temperature range
- -32 – 420 °C
- Brand
- Kern
Functions
- Rechargeable battery
- Not specified
- Display hold
- Yes
- Unit switching
- Not specified
Power supply : Battery. Battery type : Alkali(-Manganese). Quantity Batteries : 9 V Block. Power battery connector : 9V Block. Battery working period : 9 h. Power battery connected : nicht angeschlossen, beiliegend. Battery status : yes. Has electronics : yes.
Temperature sensor laser power : 0.001 W. Temperature sensor laser class : 2. Temperature stative mounting : yes.
Temperature min : -32 °C. Units : °C;°F. Temperature sensor response time : 250 ms. Sensor emisivity min : 0.1. Sensor emisivity max : 1. Temperature range1 min : -32 °C. Temperature range1 max : 0 °C. Temperature1 accuracy : +/- 1.5 °C+0.1 °C/ °C. Temperature1 coefficient : +/- 0.1 °C/ °C. Temperature1 repeatability : +/- 0.7 °C. Temperature range2 min : 0 °C. Temperature range2 max : 100 °C. Temperature 2 accuracy : +/- 1.5 °C. Temperature 2 coefficient : +/- 0.1 °C/ °C. Temperature 2 repeatability : +/- 0.7 °C. Temperature range 3 min : 100 °C. Temperature 3 accuracy : +/- 1.5%. Temperature 3 coefficient : +/- 0.1%/ °C. Temperature 3 repeatability : +/- 0.7%.
Determines the temperature of surfaces precisely. Light EBTN colour display for optimum readability under the most varied environmental conditions. MAX/MIN/AVG/DIF value memory to store the highest, lowest and average measured temperatures in a defined period of time as well as the difference between the highest and lowest value. Limit-alarm function with memory for five temperatures or emission values respectively, which trigger an audible and visual signal (three-colour LED) when the value goes below or above these values. Main application areas: Temperature measurement in industry (e.g. metal processing, machine construction), environmental engineering, agriculture, laboratory and maintenance work (e.g. wind turbines). Laser (Class 2 < 1 mW) to mark the measurement point. Locked measurement for processes where the temperature needs to be monitored, i.e. the measured values are locked and protected from external influences. With mounting hole for column mount.